
II Parameters
Base Specifications Parameters
II - 43
【#21152(PR)】 SC_EQP_2 Safety device mounting information 2
Set the devices' mount status when the device manufacturer's safety sequence is shared by
machines with different safety device configurations.
Each bit's data is copied to M808 - M815 respectively at every power ON, which may be
used in the device manufacturer's safety sequence on both NC-side and PLC-side.
Each bit corresponds to the following device No.
bit0: M808
bit1: M809
bit2: M810
bit3: M811
bit4: M812
bit5: M813
bit6: M814
bit7: M815
---Setting range---
00000000 to 11111111
【#21153(PR)】 SC_EQP_CHK1 Safety device mounting information check 1
Use this parameter to prevent the incorrect setting of "#21151 SC_EQP_1 (Safety device
mounting information 1)".
Set the same value as in "#21151 SC_EQP_1 (Safety device mounting information 1)".
Each bit's data is copied to M816 - M823 respectively at the power ON.
Each bit corresponds to the following device No.
bit0: M816
bit1: M817
bit2: M818
bit3: M819
bit4: M820
bit5: M821
bit6: M822
bit7: M823
---Setting range---
00000000 to 11111111
【#21154(PR)】 SC_EQP_CHK2 Safety device mounting information check 2
Use this parameter to prevent the incorrect setting of "#21152 SC_EQP_2 (Safety device
mounting information 2)".
Set the same value as in "#21152 SC_EQP_2 (Safety device mounting information 2)".
Each bit's data is copied to M824 - M831 respectively at the power ON.
Each bit corresponds to the following device No.
bit0: M824
bit1: M825
bit2: M826
bit3: M827
bit4: M828
bit5: M829
bit6: M830
bit7: M831
---Setting range---
00000000 to 11111111
【#21155(PR)】 Built in Safety Built-in safety circuit
Select whether to execute the built-in safety circuit.
0: Not transfer the element manufacturer's safety sequence to PLC.
Not execute the element manufacturer's safety sequence on NC-side.
1: Transfer the element manufacturer's safety sequence to PLC.
Execute the element manufacturer's safety sequence on NC-side.
【#21156(PR)】 SSU_wrg Reset Comparison error warning reset cancel
Select the operation after "Y21 Safety observation warning 0020" (Dual signal: State after
error unconfirmed) occurs.
0: Temporarily clear the warning after resetting.
The warning will be shown after the power is turned ON again.
1: Clear the warning after resetting.
The warning will not be shown after the power is turned ON again.
【#21157(PR)】 SC_EQP_3 Safety device mounting information 3
Set the devices' mount status when the device manufacturer's safety sequence is shared by
machines with different safety device configurations.
Each bit's data is copied to M832 - M839 respectively at every power ON, which may be
used in the device manufacturer's safety sequence on both NC-side and PLC-side.
Each bit corresponds to the following device No.
bit0: M832
bit1: M833
bit2: M834
bit3: M835
bit4: M836
bit5: M837
bit6: M838
bit7: M839
---Setting range---
00000000 to 11111111
Hello Guys, Glad to Join! :)