II Parameters
PLC Axis Indexing Parameters
II - 169
【#12895】 PSW13-1 PSW13 area setting 1
Set "PSW13 area setting" 1 and 2 to specify the area where the position switch 13 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12896】 PSW13-2 PSW13 area setting 2
Set "PSW13 area setting" 1 and 2 to specify the area where the position switch 13 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12897】 PSW14-1 PSW14 area setting 1
Set "PSW14 area setting" 1 and 2 to specify the area where the position switch 14 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12898】 PSW14-2 PSW14 area setting 2
Set "PSW14 area setting" 1 and 2 to specify the area where the position switch 14 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12899】 PSW15-1 PSW15 area setting 1
Set "PSW15 area setting" 1 and 2 to specify the area where the position switch 15 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12900】 PSW15-2 PSW15 area setting 2
Set "PSW15 area setting" 1 and 2 to specify the area where the position switch 15 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)