Citizen C70 Spezifikationen Seite 253

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 385
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 252
II Parameters
Position Switches
II - 160
#7654 <check> Selection of area check method PSW16
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7661 <axis> Axis name PSW17
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
#7662 <dog1> Imaginary dog position 1 PSW17
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X678
Part system 2 device: X6F8
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7663 <dog2> Imaginary dog position 2 PSW17
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X678
Part system 2 device: X6F8
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7664 <check> Selection of area check method PSW17
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7671 <axis> Axis name PSW18
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
#7672 <dog1> Imaginary dog position 1 PSW18
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X679
Part system 2 device: X6F9
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7673 <dog2> Imaginary dog position 2 PSW18
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X679
Part system 2 device: X6F9
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7674 <check> Selection of area check method PSW18
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7681 <axis> Axis name PSW19
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
#7682 <dog1> Imaginary dog position 1 PSW19
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67A
Part system 2 device: X6FA
---Setting range---
-99999.999 to 99999.999 (0.001mm)
Seitenansicht 252
1 2 ... 248 249 250 251 252 253 254 255 256 257 258 ... 384 385

Kommentare zu diesen Handbüchern

Darricknus 16 Feb 2024 | 10:14:18

Hello Guys, Glad to Join! :)